• 1

PowerAgent Online LCD UPS 1008/2016/3024

 

Online UPS Series

  • True double-conversion
  • Wide input voltage range (110-300 VAC)
  • Input power factor correction 0.99
  • Output Power Factor 0.8
  • 50Hz/60Hz frequency converter mode
  • Charger capacity expansion to 8A for long-run models
  • Emergency power off function (EPO)
  • Eco mode operation for energy saving (ECO)
  • Generator compatible
  • SNMP+USB+RS-232 multiple communications
  • Smart battery charger design for optimized battery performance
  • Selectable output voltage: 208-240VAC, 110-127VAC
  • Accessory: External maintenance bypass switch & SNMP card
 

Specifications

MODEL PowerAgent 1008
Online LCD (L)
PowerAgent 2016
Online LCD (L)
PowerAgent 3024 
Online LCD (L)
  Back Plan 4 IEC output 8 IEC output 6 IEC outpu
  CAPACITY 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W
  INPUT
  Voltage
   Range
 Low Line Transfer 160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 % or 
80 VAC / 70 VAC / 60 VAC / 50 VAC ± 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
 Low Line Comeback 175 VAC ± 5 % or 85 VAC ± 5 %
 High Line Transfer 300 VAC ± 5 % or 150 VAC ± 5 %
 High Line Comeback 290 VAC ± 5 % or 145 VAC ± 5 %
  Frequency 40 Hz ~ 70 Hz
  Phase Single phase with ground
  Power Factor ≧ 0.99 @ 220-230 VAC (input voltage)
  OUTPUT
  Output Voltage (Batt. Mode) ± 3%
  Frequency Range
   (Synchronized Range)
47 ~ 53 Hz or 57 ~ 63 Hz
  Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
  TCurrent Crest Ratio 3:1
  Harmonic Distortion ≦ 3 % THD (Linear Load), 
≦ 6 % THD (Non-linear Load)
≦ 4 % THD (Linear Load)
≦ 7 %THD (Non-linear Load)
  Transfer
   Time
 AC Mode to Batt. Mode Zero
 Inverter to Bypass 4 ms (Typical)
  Waveform (Batt. Mode) Pure Sinewave
  EFFICIENCY
  AC Mode 85% 88%
  Battery Mode 83%
  BATTERY
  Standard
   Model
 Battery Type 12 V / 7 Ah 12 V / 7 Ah 12 V / 9 Ah
 Numbers 3 6 6
 Typical Recharge Time 4 hours recover to 90% capacity
 Charging Current (max.) 1.0 A
 Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1%
  Long-run
   Model
 Battery Type Depending on the capacity of external batteries
 Numbers
 Charging Current (max.) 8.0A
 Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1%
  INDICATORS
  LCD Panel UPS status, Load level, Battery level, Input/Output voltage,
Discharge timer, and Fault conditions
  LED Panel Sixteen LEDs indicating UPS status, Load level, Battery level,
overload, fault, and programmable outlet information
  ALARM
  Battery Mode Sounding every 4 seconds
  Low Batteryl Sounding every second
  Overload Sounding twice every second
  Fault Continuously sounding
  PHYSICAL
  Tower 
   Case
 Standard
  Model
 Dimension,
  D X W X H (mm)
397 X 145 X 220 421 X 190 X 318
 Net Weight (kgs) 13 26 28
 Long-run
  Model
 Dimension,
  D X W X H (mm)
397 X 145 X 220 421 X 190 X 318
 Net Weight (kgs) 7 13 13
 Rack
  Case
 Standard
  Model
 Dimension,
  D X W X H (mm)
420x438x88[2U] 580x438x133[3U]
 Net Weight (kgs) 16 29 31
 Long-run
  Model
 Dimension,
  D X W X H (mm)
420x438x88[2U] 580x438x133[3U]
 Net Weight (kgs) 10 17 17
  ENVIRONMENT
  Operation Humidity 20-90 % RH @ 0- 40°C (non-condensing)
  Noise Level Less than 45dB @ 1 Meter
  MANAGEMENT
  Smart RS-232/USB Supports Windows 98/2000/2003/XP/Vista/2008,
Windows 7, Linux, and MAC
  Optional SNMP Power management from SNMP manager and web browser
  * * Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output
        voltage is adjusted to 208VAC.
  * L means long-run model
  * Product specifications are subject to change without further notice